3.2.1 Setup Method

( 1 ) Settings Required for Setup

The following settings are required to set up the SVA-01 Module.

[ a ] Module Configuration Definition Settings

Defines the SVA-01 Module in the MPE720's Module configuration definition.

[ b ] Saving to Flash Memory

Be sure to save the settings to flash memory in the MP2200/MP2300 using the MPE720.

( 2 ) Allocation Method

Use either of the following two methods to allocate data for the SVA-01 Module.

• Self-configuration (automatic generation of definition files) (Refer to 3.2.2 Self-configuration.)
• Set in the MPE720 Module Configuration Definition Window (Refer to 3.2.3 Module Configura-

tion Definitions.)

3.2.2 Self-configuration

Self-configuration for the SVA-01 Module automatically recognizes all the MP2200/MP2300
Optional Modules, and automatically generates definition files. Self-configuration can be used to
reduce setup time.