beautypg.com

2 motion parameter lists, 1 fixed parameter list, 1 fix – Yaskawa MP2200 Machine Controller User Manual

Page 125: 2 motion parameter lists -5, 1 fixed parameter list -5

background image

4.2 Motion Parameter Lists

4-5

4.2 Motion Parameter Lists

4.2.1 Fixed Parameter List

No. Name

Description

SVB

-01

SVA

-01

SVR

0

Run Mode

0: Normal Running

Yes

Yes

Yes

1: Axis Unused

Yes

Yes

Yes

2: Simulation Mode

Yes

Yes

3: Servo Driver Command (SERVOPACK Transparent Command
Mode)

Yes

4: General-purpose I/O mode

Yes

5: Reserved mode 1 (factory adjustment mode)

Yes

1

Function Selection 1

Bit 0: Axis Type (0: Finite length axis/1: Infinite length axis)

Yes

Yes

Yes

Bit 1: Forward Software Limit Enabled (0: Disabled/1: Enabled)

Yes

Yes

Bit 2: Reverse Software Limit Enabled (0: Disabled/1: Enabled)

Yes

Yes

Bit 3: Positive Overtravel (0: Disabled/1: Enabled)

Yes

Yes

Bit 4: Negative Overtravel (0: Disabled/1: Enabled)

Yes

Yes

Bit 5: Deceleration Limit Switch Inversion (0: Not inverted/1:
Inverted)

Yes

Bit 6: Reserved
Bit 7: Read Absolute Data after Power-up
(0: Executed/1: Not executed.)

Yes

Bit 8: Segment Distribution Processing

Yes

Bit 9: Simple ABS Infinite Axis (0: Disabled/1: Enabled)

Yes

Yes

Bit A: User Constants Self-Writing Function

Yes

Bits B to F: Reserved

2

Function Selection 2

Bit 0: Communication Error Mask

Yes

Bit 1: WDT Error Mask

Yes

Bit 2: Reserved
Bit 3: Analog Adjustment Unfinished Warning Mask
(0: Disabled/1: Enabled)

Yes

Bit 4: PG Disconnected Alarm Mask (0: Disabled/1: Enabled)
Bits 5 to F: Reserved

3

Reserved

4

Command Unit

0: pulse
1: mm
2: deg
3: inch

Yes

Yes

Yes

5

Number of Decimal Places

1 = 1 digit

Yes

Yes

Yes

6

Command Units per Revolution
(rotary motor) or
Linear Scale Pitch (linear motor)

1 = 1 reference unit

Yes

Yes

Yes

8

Gear Ratio [MOTOR]

1 = 1 rotation
This setting is ignored if a linear motor is selected.

Yes

Yes

Yes

9

Gear Ratio [LOAD]

1 = 1 rotation
This setting is ignored if a linear motor is selected.

Yes

Yes

Yes

10

Maximum Value of Rotary Counter
(POSMAX)

1 = 1 reference unit

Yes

Yes

Yes

12

Forward Software Limit

1 = 1 reference unit

Yes

Yes

This manual is related to the following products: