15 change feed forward (kfs), 15 chan, 15 change feed forward (kfs) -86 – Yaskawa MP2200 Machine Controller User Manual
Page 316: 1 ) operating procedure ( 2 ) holding and aborting, 3 ) related parameters
5 Motion Commands
5.2.15 Change Feed Forward (KFS)
5-86
5.2.15 Change Feed Forward (KFS)
The KFS command transfers the setting of the Speed Feed Forward Compensation (motion setting
parameter OW30) to the Feed Forward in the SERVOPACK and enables the setting.
( 1 ) Operating Procedure
( 2 ) Holding and Aborting
The Command Pause bit (OB090) and the Command Abort bit (OB091) cannot be used.
( 3 ) Related Parameters
[ a ] Setting Parameters
No.
Execution Conditions
Confirmation Method
1
There are no alarms.
Both IL02 and IL04 are 0.
2
Motion command execution has been completed.
IW08 is 0 and IB090 is OFF.
Execute the
KFS motion command.
• Set OW08 to 16.
• With the MECHATROLINK-II, there is the function that the change of
setting parameter is automatically updated. If utilizing this function,
there is no need to execute KFS command. For details, refer to bit A
(User Constants Self-Writing Function) in Fixed Parameter 1 (Function
Selection 1).
• The Command Pause (OB090) cannot be used.
• The Command Abort (OB091) cannot be used.
The Feed Forward is set in the SERVOPACK
and enabled.
• IW08 will be 16 during command
execution.
• IB090 will be ON during command
execution.
Parameter change completed.
• IW08 will be 16 and IB090 will be
OFF.
Execute NOP motion command.
• Set OW08 to 0.
Parameter
Name
Setting
OW08
Motion Command
The feed forward value is changed when this parameter is set to 16.
OB090
Command Pause
This parameter is ignored for KFS command.
OB091
Command Abort
This parameter is ignored for KFS command.
OW30
Speed Feed Forward
Compensation
Set the amount of Servo feed forward (%).