beautypg.com

7 read fixed parameters (fixprm_rd), 7 read fixed parameters (fixprm_rd) -124, 1 ) operating procedure ( 2 ) related parameters – Yaskawa MP2200 Machine Controller User Manual

Page 354

background image

5 Motion Commands

5.3.7 Read Fixed Parameters (FIXPRM_RD)

5-124

5.3.7 Read Fixed Parameters (FIXPRM_RD)

Reads the current value of the specified fixed parameter and stores the value in the “Fixed Parameter
Monitor” monitoring parameter.

( 1 ) Operating Procedure

( 2 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

Motion subcommand execution must be completed.

IW††0A is 0 and IB††0B0 is OFF.

Execute FIXPRM_RD motion subcommand.

• Set OW††0A to 5.

Reads the specified fixed parameter's current value
and stores the code in the monitoring parameter.

• IW††0A will be 5 during command execution.
• IB††0B0 will be ON during command

processing.

Monitoring is completed.

• IW††0A is 5 and IB††0B0 is OFF.

Execute NOP motion command.

• Set IW††0A to 0.

Parameter

Name

Setting Contents

OW††0A

Motion Subcommand

The Read Fixed Parameter subcommand is executed when this parameter is set to
5.

OW††5C

Fixed Parameter
Number

Set the parameter number of the fixed parameter to be read.

Parameter

Name

Monitoring Contents

IW††0A

Motion Subcommand
Response Code

Indicates the motion subcommand that is being executed.
The response code is 5 during FIXPRM_RD command execution.

IB††0B0

Command Executing

Turns ON during FIXPRM_RD command execution and turns OFF when execution
has been completed.

IB††0B3

Command Error End

Turns ON if an error occurs during FIXPRM_RD command execution. Turns OFF
when another command is executed.

IB††0B8

Command Execution
Completed

Turns ON when FIXPRM_RD command execution has been completed.

IL††56

Fixed Parameter
Monitor

Stores the data of the specified fixed parameter number.

This manual is related to the following products: