Yaskawa MP2200 Machine Controller User Manual
Page 215

4.4 SVA-01 Module Parameter Details
4-95
IL16
Machine Coordinate Feedback Position (APOS)
Range
Unit
−2
31
to 2
31
−1
Reference unit
Stores the feedback position in the machine coordinate system managed by the Motion Module.
• This parameter will be set to 0 when a Zero Point Return (ZRET) is executed.
(
Note) When an infinite length axis type is selected, the position ranges from 0 to (Infinite Length Axis
Reset Position
− 1).
IL18
Machine Coordinate Latch Position (LPOS)
Range
Unit
−2
31
to 2
31
−1
Reference unit
Stores the latch position when the latch has been completed.
IL1A
Position Error (PERR)
Range
Unit
−2
31
to 2
31
−1
Reference unit
Stores the following error (Machine Coordinate System Position (IL12)
− Machine Coordinate Feedback Position
(IL16)) managed by the Motion Module.
IL1C
Reference Position Increment Monitor
Range
Unit
−2
31
to 2
31
−1
Reference unit
Stores the pulse distribution amount calculated every 500
µs cycle.
IW1E
POSMAX Number of Turns
Range
Unit
−2
31
to 2
31
−1
Rev
This parameter is valid for an infinite length axis.
The count stored in this parameter goes up and down every time the current position exceeds the Maximum Value of Rotary
Counter (POSMAX) (fixed parameter 10).
(cont’d)