6.1 SVB-01 Module Control Block Diagrams
6-15
[ b ] Setting Parameters
No.
Name
Setting Unit
Default Value
Setting Range
OW00
RUN Commands
−
0000h
Bit setting
OW01
Mode 1
−
0000h
Bit setting
OW02
Mode 2
−
0000h
Bit setting
OW03
Function 1
−
0011h
Bit setting
OW04
Function 2
−
0033h
Bit setting
OW05
Function 3
−
0000h
Bit setting
OW08
Motion Command
−
0
0 to 26
OW09
Motion Command Options
−
0000h
Bit setting
OW0A
Motion Subcommand
−
0
0 to 65535
OL0C
Torque Reference
Depends on torque unit.
0
−2
31
to 2
31
−1
OW0E
Speed Limit at Torque Reference
0.01%
15000
−32768 to 32767
OL10
Speed Reference
Depends on speed unit.
3000
−2
31
to 2
31
−1
OL14
Positive Side Limiting Torque Setting at the Speed
Reference
Depends on torque unit.
30000
−2
31
to 2
31
−1
OL16
Secondary Speed Compensation
Depends on speed unit.
0
−2
31
to 2
31
−1
OW18
Speed Override
0.01%
10000
0 to 32767
OL1C
Position Reference Setting
Reference unit
0
−2
31
to 2
31
−1
OL1E
Positioning Completed Width
Reference unit
100
0 to 65535
OL20
Positioning Completed Width 2
Reference unit
0
0 to 65535
OL22
Deviation Abnormal Detection Value
Reference unit
2
31
−1
0 to 2
31
−1
OW26
Position Complete Timeout
ms
0
0 to 65535
OL28
Phase Compensation
Reference unit
0
−2
31
to 2
31
−1
OL2A
Latch Zone Lower Limit
Reference unit
−2
31
−2
31
to 2
31
−1
OL2C
Latch Zone Upper Limit
Reference unit
2
31
−1
−2
31
to 2
31