beautypg.com

B ] setting parameters – Yaskawa MP2200 Machine Controller User Manual

Page 371

background image

6.1 SVB-01 Module Control Block Diagrams

6-15

[ b ] Setting Parameters

No.

Name

Setting Unit

Default Value

Setting Range

OW††00

RUN Commands

0000h

Bit setting

OW††01

Mode 1

0000h

Bit setting

OW††02

Mode 2

0000h

Bit setting

OW††03

Function 1

0011h

Bit setting

OW††04

Function 2

0033h

Bit setting

OW††05

Function 3

0000h

Bit setting

OW††08

Motion Command

0

0 to 26

OW††09

Motion Command Options

0000h

Bit setting

OW††0A

Motion Subcommand

0

0 to 65535

OL††0C

Torque Reference

Depends on torque unit.

0

−2

31

to 2

31

−1

OW††0E

Speed Limit at Torque Reference

0.01%

15000

−32768 to 32767

OL††10

Speed Reference

Depends on speed unit.

3000

−2

31

to 2

31

−1

OL††14

Positive Side Limiting Torque Setting at the Speed
Reference

Depends on torque unit.

30000

−2

31

to 2

31

−1

OL††16

Secondary Speed Compensation

Depends on speed unit.

0

−2

31

to 2

31

−1

OW††18

Speed Override

0.01%

10000

0 to 32767

OL††1C

Position Reference Setting

Reference unit

0

−2

31

to 2

31

−1

OL††1E

Positioning Completed Width

Reference unit

100

0 to 65535

OL††20

Positioning Completed Width 2

Reference unit

0

0 to 65535

OL††22

Deviation Abnormal Detection Value

Reference unit

2

31

−1

0 to 2

31

−1

OW††26

Position Complete Timeout

ms

0

0 to 65535

OL††28

Phase Compensation

Reference unit

0

−2

31

to 2

31

−1

OL††2A

Latch Zone Lower Limit

Reference unit

−2

31

−2

31

to 2

31

−1

OL††2C

Latch Zone Upper Limit

Reference unit

2

31

−1

−2

31

to 2

31

−1

This manual is related to the following products: