Yaskawa MP2200 Machine Controller User Manual

Page 126

background image

4 Motion Parameters

4.2.1 Fixed Parameter List

4-6

14

Reverse Software Limit

1 = 1 reference unit

Yes

Yes

16

Backlash Compensation

1 = 1 reference unit

Yes

Yes

18

Reserved

20

Hardware Signal 1

Bit 0: Pulse A/B Input Signal Polarity
(0: Positive logic/1: Negative logic)

Yes

Bit 1: Pulse C Input Signal Polarity
(0: Positive logic/1: Negative logic)

Yes

Bits 2 to F: Reserved

21

Hardware Signal 2

Bit 0: Deceleration Limit Switch Signal
(0: Use setting parameter/1: Use the DI signal)

Yes

Bits 1 to F: Reserved

22

Pulse Count Mode Selection

0: Sign mode (Input pulse multiplier: 1)
1: Sign mode (Input pulse multiplier: 2)
2: Up/Down mode (Input pulse multiplier: 1)
3: Up/Down mode (Input pulse multiplier: 2)
4: Pulse A/B mode (Input pulse multiplier: 1)
5: Pulse A/B mode (Input pulse multiplier: 2)
6: Pulse A/B mode (Input pulse multiplier: 4)

Yes

23

D/A Output Voltage at 100% Speed

1 = 0.001 V

Yes

24

D/A Output Voltage at 100% Torque 1 = 0.001 V

Yes

25

Reserved

26

A/D Input Voltage at 100% Torque
Monitor

1 = 0.001 V

Yes

27

Reserved

28

Servo Driver Series

0:

Σ-I

1:

Σ-II/Σ-III

2: Reserved

Yes

29

Motor Type

0: Rotary motor
1: Linear motor

Yes

Yes

30

Encoder Type

0: Incremental encoder
1: Absolute encoder
2: Absolute encoder used as an incremental encoder.
3: Reserved

Yes

Yes

31

Rotational Direction of Absolute
Encoder

0: Forward
1: Reverse

Yes

32

Reserved

34

Rated Speed (Rotary Motor or
Linear Motor)

1 = 1 min

-1

(with rotary motor)

or
1 = 0.1 m/s (with linear motor)

Yes

Yes

Yes

36

Encoder Resolution in Pulses/
Revolution (Rotary Motor)

1 = 1 pulse/rev
Set the value before multiplication.
Refer to ( 2 ) SVA-01 Module Fixed Parameter Settings under 3.2.4
Servo Parameter Settings
fo
r setting methods.

Yes

1 = 1 pulse/rev
Set the value before multiplication.

Yes

Yes

Encoder Output Resolution per
Linear Scale Pitch (Linear Motor)

1 = 1 pulse/linear scale pitch
Set the value before multiplication.
Refer to ( 2 ) SVA-01 Module Fixed Parameter Settings under 3.2.4
Servo Parameter Settings
fo
r setting methods.

Yes

1 = 1 pulse/linear scale pitch
Set the value before multiplication.

Yes

(cont’d)

No. Name

Description

SVB

-01

SVA

-01

SVR

This manual is related to the following products: