8 SVR Virtual Motion Module
8.3.2 Motion Command Details
8-28
[ b ] Related Parameters
■
Setting Parameters
■
Monitoring Parameters
Parameter
Name
Setting
OB000
Servo ON
Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor, 0: Power OFF to Servomotor
Set this bit to 1 before setting the Motion Command (OW08) to 6.
OW03
Function 1
Set the speed unit, acceleration/deceleration unit, and filter type.
OW08
Motion Command
The positioning starts when this parameter is set to 6.
OB095
Position Reference
Type
Switch the type of position reference.
0: Incremental addition mode, 1: Absolute mode
Set this parameter before setting the Motion Command (OW08) to 6.
OL1C
Position Reference
Setting
Set the target position for positioning. The setting can be changed every high-speed
scan.
OW3A
Filter Time Constant
Set the acceleration/deceleration filter time constant. Exponential acceleration/
deceleration or a moving average filter can be selected in OW03.
Change the setting only after pulse distribution has been completed for the command
(IB0C0 is ON).
Parameter
Name
Monitor Contents
IB001
Servo ON
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates motion commands during execution.
The response code is 6 during LATCH operation.
IB090
Command Executing
Always OFF for LATCH operation.
IB091
Command Hold
Completed
Always OFF for LATCH operation.
IB093
Command Error End
Turns ON if an error occurs during LATCH operation. The axis will decelerate to a stop
if it is moving. Turns OFF when another command is executed.
IB098
Command Execution
Completed
Always OFF for LATCH operation.
IB0C0
Distribution
Completed
Turns ON when distribution has been completed for the move command.
Turns OFF during execution of a move command.
IB0C1
Positioning
Completed
Turns ON when pulse distribution has been completed. OFF in all other cases.
IB0C3
Position Proximity
Turns ON when Distribution Completed (DEN) turns ON.