M ] home ls signal method (ow3c = 15) – Yaskawa MP2200 Machine Controller User Manual
Page 274

5 Motion Commands
5.2.3 Zero Point Return (ZRET)
5-44
(
Note) Reverse type in
: Parameters only for the SVA-01 Module.
[ m ] Home LS Signal Method (OW3C = 15)
Travel is started at the creep speed in the direction specified by the sign of the creep speed. When the
rising edge of the home signal is detected, positioning is performed at the positioning speed. When
positioning has been completed, a machine coordinate system is established with the final position as
the zero point.
The moving
amount after the home signal is detected is set in the Home Offset. The positioning
speed is set in the Speed Reference Setting. If an OT signal is detected during creep speed operation,
an OT alarm will not occur, the direction will be reversed, and a search will be made for the home
signal. If an OT signal is detected during positioning speed operation, an OT alarm will occur.
Fixed
Parameter
No. 1, Bit 5
Deceleration Limit Switch
Inversion
Set whether or not to invert the polarity of the DI_5 signal, which is used for HOME.
(OW05, bit 8, will not reverse status.)
HOME signal
*1
NOT
*3
POT
*2
Start
Zero Point
Creep Speed
(OL
40)
Home Offset
(OL
42)
Positioning Speed
(OL
10)