Yaskawa MP2200 Machine Controller User Manual
Page 81

3.1 SVB-01 Module Setup
3-9
MECHATROLINK Transmission Definitions for SVB in MP2300 CPU
The MECHATROLINK transmission definition is automatically set according to the detected
communication method and number of slaves.
* The communication cycle and number of retry stations in MECHATROLINK-II 32-byte Mode
change according to the highest station number of the detected slaves, as shown in the
following table.
Slave Devices Not Recognized by Self-configuration
The following slave devices (I/O Module) are detected as wildcard I/O (***** I/O), because no type
code exists for them. Therefore, allocate these slaves again using the MPE720’s Module Configuration
Definition Window.
• JEPMC-IO350
• JAMSC-120DAI53330
• JAMSC-120DAI73330
• JAMSC-120DAO83330
• JAMSC-120DRA83030
SERVOPACKs with special specifications that cannot be automatically detected are recognized as
wildcard SERVOPACKs (***** SERVO). Therefore, allocate these SERVOPACKs again using the
MPE720’s Module Configuration Definition Window.
INFO
Communication
Method
MECHATROLINK-II
(32 Bytes)
MECHATROLINK-II
(17 Bytes)
MECHATROLINK-I
Transmission speed
10 Mbps
10 Mbps
4 Mbps
Transmission byte
32
17
17
Communication
cycle
1 ms
*
2 ms
*
1 ms
2 ms
Number of slaves
*
*
14
15
14
No. of retry to slaves
*
*
1
0
−
SigmaWin
Not use
Not use
−
Highest Slave Station
Number
Communication
cycle (ms)
No. of retry to slaves
1 to 8
1
1
9
1
0
10 to 16
2
5
17 to 21
2
Determined by the following
equation.
21 – (Highest station number)