C ] monitoring parameters – Yaskawa MP2200 Machine Controller User Manual
Page 379

6.1 SVB-01 Module Control Block Diagrams
6-23
[ c ] Monitoring Parameters
No.
Name
Unit
Default Value
Range
IW00
Drive Status
−
−
Bit setting
IW01
Over Range Parameter Number
−
−
0 to 65535
IL02
Warning
−
−
Bit setting
IL04
Alarm
−
−
Bit setting
IW08
Servo Command Type Response
−
−
0 to 65535
IW09
Servo Module Command Status
−
−
Bit setting
IW0A
Motion Subcommand Response Code
−
−
0 to 65535
IW0B
Motion Subcommand Status
−
−
Bit setting
IW0C
Position Management Status
−
−
Bit setting
IL0E
Machine Coordinate Target Position (TPOS)
Reference unit
−
−2
31
to 2
31
−1
IL10
Target Position (CPOS)
Reference unit
−
−2
31
to 2
31
−1
IL12
Machine Coordinate System Position (MPOS)
Reference unit
−
−2
31
to 2
31
−1
IL16
Machine Coordinate Feedback Position (APOS)
Reference unit
−
−2
31
to 2
31
−1
IL18
Machine Coordinate Latch Position (LPOS)
Reference unit
−
−2
31
to 2
31
−1
IL1A
Position Error (PERR)
Reference unit
−
−2
31
to 2
31
−1
IL1C
Target Position Difference Monitor
Reference unit
−
−2
31
to 2
31
−1
IL1E
POSMAX Number of Turns
Reference unit
−
−2
31
to 2
31
−1
IL20
Speed Reference Output Monitor
pulse/s
−
−2
31
to 2
31
−1
IW2C
Network Servo Status
−
−
Bit setting
IW2D
Servo Alarm Code
−
−
−32768 to 32767
IW2E
Network Servo I/O Monitor
−
−
Bit setting
IW2F
Network Servo User Monitor Information
−
−
Bit setting
IL30
Servo User Monitor 2
−
−
−2
31
to 2
31
−1
IL34
Servo User Monitor 4
−
−
−2
31
to 2
31
−1
IW36
Servo Constant Number
−
−
0 to 65535
IW37
Auxiliary Servo User Constant Number
−
−
0 to 65535
IL38
Servo User Constant
−
−
−2
31
to 2
31
−1
IL3A
Auxiliary Servo User Constant
−
−
−2
31
to 2
31
−1
IW3F
Motor Type
−
−
0, 1
IL40
Feedback Speed
Depends on speed unit.
−
−2
31
to 2
31
−1
IL42
Torque (Thrust) Reference Monitor
Depends on torque unit.
−
−2
31
to 2
31
−1
IL56
Fixed Parameter Monitor
−
−
−2
31
to 2
31
−1
IL5E
Absolute Position at Power OFF (Low Value)
pulse
−
−2
31
to 2
31
−1
IL60
Absolute Position at Power OFF (High Value)
pulse
−
−2
31
to 2
31
−1
IL62
Modularized Position at Power OFF (Low Value)
pulse
−
−2
31
to 2
31
−1
IL64
Modularized Position at Power OFF (High Value)
pulse
−
−2
31
to 2
31
−1