B ] setting parameters – Yaskawa MP2200 Machine Controller User Manual
Page 365

6.1 SVB-01 Module Control Block Diagrams
6-9
[ b ] Setting Parameters
No.
Name
Setting Unit
Default Value
Setting Range
OW00
RUN Commands
−
0000h
Bit setting
OW01
Mode 1
−
0000h
Bit setting
OW02
Mode 2
−
0000h
Bit setting
OW03
Function 1
−
0011h
Bit setting
OW04
Function 2
−
0033h
Bit setting
OW05
Function 3
−
0000h
Bit setting
OW08
Motion Command
−
0
0 to 26
OW09
Motion Command Options
−
0000h
Bit setting
OW0A
Motion Subcommand
−
0
0 to 65535
OL0C
Torque Reference
Depends on torque unit.
0
−2
31
to 2
31
−1
OW0E
Speed Limit at Torque Reference
0.01%
15000
−32768 to 32767
OL10
Speed Reference
Depends on speed unit.
3000
−2
31
to 2
31
−1
OL14
Positive Side Limiting Torque Setting at the Speed
Reference
Depends on torque unit.
30000
−2
31
to 2
31
−1
OL16
Secondary Speed Compensation
Depends on speed unit.
0
−2
31
to 2
31
−1
OW18
Speed Override
0.01%
10000
0 to 32767
OL1C
Position Reference Setting
Reference unit
0
−2
31
to 2
31
−1
OL1E
Positioning Completed Width
Reference unit
100
0 to 65535
OL20
Positioning Completed Width 2
Reference unit
0
0 to 65535
OL22
Deviation Abnormal Detection Value
Reference unit
2
31
−1
0 to 2
31
−1
OW26
Position Complete Timeout
ms
0
0 to 65535
OL28
Phase Compensation
Reference unit
0
−2
31
to 2
31
−1
OL2A
Latch Zone Lower Limit
Reference unit
−2
31
−2
31
to 2
31
−1
OL2C
Latch Zone Upper Limit
Reference unit
2
31
−1
−2
31
to 2
31
−1
OW2E
Position Loop Gain
0.1/s
300
0 to 32767
OW2F
Speed Loop Gain
Hz
40
1 to 2000
OW30
Speed Feed Forward Compensation
0.01%
0
0 to 32767
OW31
Speed Amends
0.01%
0
−32768 to 32767
OW32
Position Integration Time Constant
ms
0
0 to 32767
OW34
Speed Integration Time Constant
0.01 ms
2000
15 to 65535
OL36
Linear Acceleration Time
Depends on acceleration/
deceleration speed unit.
0
0 to 2
31
−1
OL38
Linear Deceleration Time
Depends on acceleration/
deceleration speed unit.
0
0 to 2
31
−1
OW3A
S-curve Acceleration Time
0.1 ms
0
0 to 65535
OW3C
Home Return Type
−
0
0 to 19
OW3D
Home Window
Reference unit
100
0 to 65535
OL3E
Approach Speed
Depends on speed unit.
1000
−2
31
to 2
31
−1
OL40
Creep Speed
Depends on speed unit.
500
−2
31
to 2
31
−1
OL42
Home Offset
Reference unit
0
−2
31
to 2
31
−1
OL44
Step Distance
Reference unit
1000
0 to 2
31
−1
OL46
External Positioning Move Distance
Reference unit
0
−2
31
to 2
31
−1
OL48
Zero Point Offset
Reference unit
0
−2
31
to 2
31
−1
OL4A
Work Coordinate System Offset
Reference unit
0
−2
31
to 2
31
−1