Yaskawa MP2200 Machine Controller User Manual
Page 85

3.1 SVB-01 Module Setup
3-13
( 2 ) Module Configuration Definition Settings
[ a ] Setting Items
The setting names and details for the Module configuration definition are shown in the following
table.
I/O Start Register Numbers and End Register Numbers
• Setting range: 0000 to 7FFF hex
• Up to 400 hex words are allocated per SVB-01 Module.
• Make sure that the register number ranges for the Modules do not overlap with each other.
• The I/O start and end register numbers must be set even if no I/O Module is connected to
MECHATROLINK.
[ b ] Saving Module Configuration Definitions
Nothing has been set immediately after installation, so be sure to save the data at least one time.
1.
Select File
− Save from the menus.
2.
Verify the displayed message and click the Yes Button to save the definition data.
[ c ] Deleting Module Configuration Definitions
When deleting the module configuration definitions file, the definition files for all the individual
Modules are also deleted.
1.
Select File
− Delete from the menus.
2.
Verify the displayed message and click the Yes Button to delete the definition data.
Setting
Details
Slot Number
Displays the slot number.
Module Type
Sets the Module to be installed in each slot.
Circuit Number
Sets the circuit number in order from 01 for the Module.
I/O Start Register
Sets the I/O register start (leading) address for the I/O Modules connected to
MECHATROLINK.
I/O End Register
Sets the I/O register ending address for the I/O Modules connected to
MECHATROLINK.
Input DISABLE
Sets to enable/disable the input registers.
Blank: Setting not allowed, D: Disabled, E: Enabled
Output DISABLE
Sets to enable/disable the output registers.
Blank: Setting not allowed, D: Disabled, E: Enabled
Motion Start Register
Sets the start address for the motion parameters register. This address is set
automatically according to the circuit number.
Motion End Register
Sets the end address for the motion parameters register. This address is set
automatically according to the circuit number.
Detail
Sets the MECHATROLINK transmission definitions.
Double-click MECHATROLINK to open the MECHATROLINK Transmission
Configuration Window.
Status
Displays each Module’s status when online.
INFO