4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual
Page 323

5.2 Motion Command Details
5-93
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 19 during ALM_MON command execution.
IB090
Command Executing
Turns ON during ALM_MON command execution and turns OFF when execution has
been completed.
IB091
Command Hold
Completed
Always OFF for ALM_MON command.
IB093
Command Error End
Turns ON if an error occurs during ALM_MON command execution. Turns OFF when
another command is executed.
IB098
Command Execution
Completed
Turns ON when ALM_MON command execution has been completed.
IW2D
Servo Alarm Code
Stores the SERVOPACK alarm or warning code that was read.
OW
08 = 19 (ALM_MON)
IW
08 = 19 (ALM_MON)
IB
090 (BUSY)
IW
2D
Alarm code (0)
Alarm code (0)
Specified
alarm
code
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length
of time
Alarm code (0)
Alarm
code (0)
Alarm
code (0)
OW
08 = 19 (ALM_MON)
IW
08 = 19 (ALM_MON)
IB
090 (BUSY)
IW
2D
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length
of time