2 sva-01 module motion parameter register numbers, 2 sv – Yaskawa MP2200 Machine Controller User Manual
Page 124

4 Motion Parameters
4.1.2 SVA-01 Module Motion Parameter Register Numbers
4-4
4.1.2 SVA-01 Module Motion Parameter Register Numbers
The motion parameter register numbers (I or O register numbers) are determined by the module
number and axis (axes 1 to 16).
Motion parameter register numbers can be obtained using the following equation.
Motion parameters register number =
I(O)W 8000 + (Module number
− 1)
×
800 hex + (Axis number
− 1)
×
80 hex
The following tables lists the motion parameters register numbers.
The maximum number of axes that can be allocated per Module differs for the MP2300 and MP2200.
The maximum numbers of axes are given in the following table.
Module No.
Axis No. 1
Axis No. 2
1
8000 to 807F
8080 to 80FF
2
8800 to 887F
8880 to 88FF
3
9000 to 907F
9080 to 90FF
4
9800 to 987F
9880 to 98FF
5
A000 to A07F
A080 to A0FF
6
A800 to A87F
A880 to A8FF
7
B000 to B07F
B080 to B0FF
8
B800 to B87F
B880 to B8FF
9
C000 to C07F
C080 to C0FF
10
C800 to C87F
C880 to C8FF
11
D000 to D07F
D080 to D0FF
12
D800 to D87F
D880 to D8FF
13
E000 to E07F
E080 to E0FF
14
E800 to E87F
E880 to E8FF
15
F000 to F07F
F080 to F0FF
16
F800 to F87F
F880 to F8FF
MP2000 Series
Number of
Modules
Maximum Number
of Axes
MP2300
0 to 2
4 axes
MP2200
1-rack configuration
0 to 7
14 axes
2-rack configuration
0 to 14
28 axes
3-rack configuration
0 to 16
32 axes
4-rack configuration
INFO