3 ) related parameters, 4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual
Page 303

5.2 Motion Command Details
5-73
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
( 4 ) Timing Charts
■
Normal Execution
Parameter
Name
Setting
OW08
Motion Command
Set to 9 for ZSET command.
OB090
Command Pause
This parameter is ignored for ZSET command.
OB091
Command Abort
This parameter is ignored for ZSET command.
OL48
Zero Point Offset
Sets the offset from the zero point in the machine coordinate system after the zero point
has been set.
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 9 during ZSET command execution.
IB090
Command Executing
Turns ON during ZSET command execution and turns OFF when ZSET command
execution has been completed.
IB091
Command Hold
Completed
Always OFF for ZSET command.
IB093
Command Error End
Turns ON if an error occurs during ZSET command execution. Turns OFF when
another command is executed.
IB098
Command Execution
Completed
Turns ON when ZSET command execution has been completed.
IB0C5
Zero Point Return
(Setting) Completed
Turns ON when the zero point has been established.
OW
08 = 9 (ZSET)
IW
08 = 9 (ZSET)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
0C5 (ZRNC)
IB
093 (FAIL)