5 ) timing charts, A ] normal execution [ b ] execution when aborted – Yaskawa MP2200 Machine Controller User Manual
Page 296

5 Motion Commands
5.2.6 JOG Operation (FEED)
5-66
( 5 ) Timing Charts
[ a ] Normal Execution
[ b ] Execution when Aborted
IB0C0
Distribution
Completed
Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.
IB0C1
Positioning
Completed
Turns ON when pulse distribution has been completed and the current position is
within the Positioning Completed Width. OFF in all other cases.
IB0C3
Position Proximity
The operation depends on the setting of the Positioning Completed Width 2 (setting
parameter OL20).
OL20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
OL20
≠ 0: Turns ON when MPOS - APOS< Position Proximity Setting even
if pulse distribution has not been completed.
OFF in all other cases.
(cont’d)
Parameter
Name
Monitor Contents
OW
08 = 7 (FEED)
IW
08 = 7 (FEED)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
IB
0C0 (DEN)
1 scan
1 scan
OB
091 (ABORT)
OW
08 = 7 (FEED)
IW
08 = 7 (FEED)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
IB
0C0 (DEN)