3 ) related parameters, 4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual
Page 311

5.2 Motion Command Details
5-81
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
Parameter
Name
Setting
OW03
Function 1
Set the speed unit, acceleration/deceleration unit, and filter type.
OW08
Motion Command
The filter type is changed when this parameter is set to 13.
OB090
Command Pause
This parameter is ignored for CHG_FILTER command.
OB091
Command Abort
This parameter is ignored for CHG_FILTER command.
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command Type
Response
Indicates the motion command that is being executed.
The response code will be 13 during CHG_FILTER command execution.
IB090
Command Executing
Turns ON during CHG_FILTER command execution and turns OFF when execution
has been completed.
IB091
Command Hold
Completed
Always OFF for CHG_FILTER command.
IB093
Command Error End
Turns ON if an error occurs during CHG_FILTER command execution. Turns OFF
when another command is executed.
IB098
Command Execution
Completed
Turns ON when CHG_FILTER command execution has been completed.
OW
08 = 13 (CHG_FILTER)
IW
08 = 13 (CHG_FILTER)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
1 scan
OW
08 = 13 (CHG_FILTER)
IW
08 = 13 (CHG_FILTER)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB