5 Motion Commands
5.2.24 Phase References (PHASE)
5-112
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal Execution
Parameter
Name
Monitor Contents
IB001
Servo ON
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 25 during PHASE command execution.
IB090
Command Executing
Always OFF for PHASE command.
IB091
Command Hold
Completed
Always OFF for PHASE command.
IB093
Command Error End
Turns ON if an error occurs during PHASE command execution. The axis will
decelerate to a stop if it is moving. Turns OFF when another command is executed.
IB098
Command Execution
Completed
Always OFF for PHASE command.
IB0C0
Distribution
Completed
Turns ON when pulse distribution has been completed for the move command. Turns
OFF during execution of a move command.
IB0C1
Positioning
Completed
Turns ON when pulse distribution has been completed and the current position is within
the positioning completed range. OFF in all other cases.
IB0C3
Position Proximity
The operation of this bit depends on the setting of Positioning Completed Width 2
(setting parameter OL20).
• OL20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
• OL20
≠ 0: Turns ON when the absolute value of the difference between the
Machine Coordinate Feedback Position (monitoring parameter IL16) and the
Machine Coordinate System Position (monitoring parameter IL12) is less than
the Position Completed Width 2, even if pulse distribution has not been completed.
OFF in all other cases.
OW
08 = 25 (PHASE)
IW
08 = 25 (PHASE)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
IB
0C0 (DEN)
1 scan
IB
0C1 (POSCOMP)
The Target Position is automatically refreshed every scan.
Undefined length of time