5.2 Motion Command Details
5-77
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
Parameter
Name
Setting
OW03
Function 1
Set the speed unit, acceleration/deceleration unit, and filter type.
OW08
Motion Command
The linear deceleration time constant is changed when this parameter is set to 11.
OB090
Command Pause
This parameter is ignored for DCC command.
OB091
Command Abort
This parameter is ignored for DCC command.
OL38
Linear Deceleration
Time
Set the deceleration for feeding as the deceleration time.
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 11 during DCC command execution.
IB090
Command Executing
Turns ON during DCC command execution and turns OFF when execution has been
completed.
IB091
Command Hold
Completed
Always OFF for DCC command.
IB093
Command Error End
Turns ON if an error occurs during DCC command execution. Turns OFF when another
command is executed.
IB098
Command Execution
Completed
Turns ON when DCC command execution has been completed.
OW
08 = 11 (DCC)
IW
08 = 11 (DCC)
IB
090 (BUSY)
Undefined length
of time
IB
098 (COMPLETE)
IB
093 (FAIL)
OW
08 = 11 (DCC)
IW
08 = 11 (DCC)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length
of time