beautypg.com

Yaskawa MP2200 Machine Controller User Manual

Page 102

background image

3 Motion Module Setup

3.2.3 Module Configuration Definitions

3-30

( 2 ) Module Configuration Definition Settings

[ a ] Setting Items

The setting names and details for the Module configuration definition are shown in the following
table.

[ b ] Saving Module Configuration Definitions

1.

Select File

Save from the menus.

2.

Verify the displayed message and click the Yes Button to save the definition data.

[ c ] Deleting Module Configuration Definitions

1.

Select File

Delete from the menus.

2.

Verify the displayed message and click the Yes Button to delete the definition data.

[ d ] Ending the Module Configuration Definitions

Select File

Close from the menus to return to the Module Configuration Definition Window.

Setting

Details

Slot Number

Displays the slot number.

Module Type

Sets the Module to be installed in each slot.

Circuit Number

Sets the circuit number for the Module.

I/O Start Register

Reserved

I/O End Register

Reserved

Motion Start Register

Sets the start address for the motion parameters register. This address is set
automatically according to the circuit number.

Motion End Register

Sets the end address for the motion parameters register. This address is set
automatically according to the circuit number.

Detail

Status

Displays each Module’s status when online.

This manual is related to the following products: