5 Motion Commands

5.2.3 Zero Point Return (ZRET)

5-46

[ n ] NOT & Phase-C Pulse Method (OW††3C = 16)

Travel is started at the approach speed in the negative direction until the stroke limit is reached.
When the NOT signal is detected, the direction is reversed to return at creep speed. When the phase-
C pulse is detected during the return after passing the NOT signal, positioning is performed. When
positioning has been completed, a machine coordinate system is established with the final position as
the zero point.
The moving

amount after the phase-C pulse is detected is set in the Home Offset. The positioning

speed is set in the Speed Reference. If a positive value is set for the approach speed, the command
will end in an error. If an OT signal is detected during the positioning speed operation, an OT alarm
will occur.

* 1. The SERVOPACK P-OT signal.
* 2. The SERVOPACK N-OT signal.

Note)The stopping method when the OT signal is detected depends on the setting of

SERVOPACK parameters.

Note) Reverse type in

: Parameters only for the SVA-01 Module.

Positioning Speed

(OL

10)

Approach Speed

(OL

3E)

Phase-C pulse

NOT

*2

POT

*1

Start

Zero Point

Creep Speed

(OL

40)

Home Offset

(OL

42)

Parameter

Name

Setting

OW††3C

Home Return Type

16: NOT & C pulse Method

OL††10

Speed Reference

Set the positioning speed to use after detecting the phase-C pulse. The
sign is ignored. The travel direction will depend on the sign of the Home
Offset.

OL††18

Speed Override

This parameter allows the Zero Point Return speed to be changed
without changing the Speed Reference (OL††10). Set the
override value as a percentage of the Speed Reference. This
setting can be changed during operation.
Setting range: 0 to 32767 (0% to 327.67%);
Setting unit: 1 = 0.01%

OL††3E

Approach Speed

Set the speed to use when starting a zero point return. Add a sign so that
the travel direction will be negative.

OL††40

Creep Speed

Set the speed to use after detecting the NOT signal. The travel direction
will be positive.

OL††42

Home Offset

Set the travel distance from the point where a phase-C pulse is detected.
The travel direction will depend on the sign.

This manual is related to the following products: