Important – Yaskawa MP2200 Machine Controller User Manual
Page 252
5 Motion Commands
5.2.3 Zero Point Return (ZRET)
5-22
■
Starting the Zero Point Return in the Low Region
1.
The axis travels in the reverse direction at the Approach Speed (setting parameter
OL3E).
2.
When the rising edge of the DEC2 signal is detected, the axis decelerates to a stop.
3.
After decelerating to a stop, the axis travels in the forward direction at the Creep
Speed (setting parameter OL40).
4.
After the falling edge of the DEC2 signal is detected, the position is latched when the
rising edge of the ZERO signal is detected.
5.
The axis moves from the latched position by the distance set in the Home Offset
(setting parameter OL42) and stops. The machine coordinate system is
established with this final position as the zero point.
If an OT signal is detected during the zero point return operation, an OT alarm will occur.
Start
DEC2
(DI_5 or OW
05, bit 8)
N-OT
(DI_4)
P-OT
(DI_3)
Approach Speed (OL
3E)
High region
Low region
End
Home Offset
ZERO signal
latch at this point
Creep Speed
(OL
40)
ZERO signal
(DI_2)
IMPORTANT