3.1 SVB-01 Module Setup

3-21

Update Current Value

This function is enabled only for servo parameters. Current values are not automatically updated
when the servo parameters are displayed. Select View

Update Current Value to read and display

the most recent values.
The following table shows the functions given above.

* Possible when the servo is ON.

Note)Yes: Operation possible, NO: Operation not possible.

[ c ] Motion Parameter Settings

Fixed Parameters Tab Page

Set the parameters required for motion control on the Fixed Parameters Tab Page.

For details on each of the fixed parameter settings, refer to 4.3.1 Motion Fixed Parameter Details.

Motion Fixed

Parameters

Motion Setting

Parameters

SERVOPACK

Parameters*

Motion

Monitoring

Parameters

Remarks

Axis Data Copy /Axis
Data Paste

Yes

Yes

No

No

Details

Yes

Yes

No

Yes

Parameters in bit
format only

Default Set

Yes

Yes

Yes

No

Copy Current Value

No

No

Yes

No

Enabled only when
online

Update Current
Value

No

No

Yes

No

Enabled only when
online

Setting

Details

Axis Number

Select the desired axis number. Set the fixed parameters for each axis.

SERVOPACK

Displays the type of SERVOPACK.

Version

Displays the version of SERVOPACK.

Servo Type
(Motor Type)

Displays the motor type.

No.

Displays the parameter number of the motion fixed parameter.

Name (Parameter Name)

Displays the parameter name.

Input Data (Set Data)

Input (or select) the parameter value.

Unit

Displays the units of the corresponding parameter.

INFO