4.3 SVB-01 Module Parameter Details
4-57
( 15 ) SERVOPACK User Monitor Information
The Monitor Selection made by the user when using a SERVOPACK for MECHATROLINK
communication is stored in this parameter.
( 16 ) SERVOPACK Information 2
IW2F
Network Servo User Monitor Information
Range
Unit
−
−
IW2F
Bit 0 to
Bit 3
Monitor 1
Bit 4 to
Bit 7
Monitor 2
Bit 8 to
Bit B
Monitor 3
Bit
C
to
Bit F
Monitor 4
IL30
Servo User Monitor 2
Range
Unit
−2
31
to 2
31
−1
−
Stores the result of the selected monitor.
This parameter stores the result of the monitor selected for Monitor 2 in the Servo User Monitor (setting parameter OW4E,
bits 4 to 7).
(
Note) This parameter can be used when the communication method is MECHATROLINK-I or
MECHATROLINK-II, 17-byte Mode and bit 0 of OW02 is set to 1 (1: Enabled).
IL32
Servo User Monitor 3
Range
Unit
−2
31
to 2
31
−1
−
Reserved.
IL34
Servo User Monitor 4
Range
Unit
−2
31
to 2
31
−1
−
Stores the result of the selected monitor.
This parameter stores the result of the monitor selected for Monitor 4 of the Servo User Monitor (setting parameter OW4E,
bits C to F).
IW36
Servo Constant Number
Range
Unit
0 to 65535
−
Stores the number of the parameter being processed.
This parameter stores the number of the SERVOPACK parameter being read or written using the MECHATROLINK command
area. Refer to Chapter 5 Motion Commands for details.
IW37
Auxiliary Servo User Constant Number
Range
Unit
0 to 65535
−
Stores the number of the parameter being processed.
This parameter stores the number of the SERVOPACK parameter being read or written using the MECHATROLINK
subcommand area. Refer to Chapter 5 Motion Commands for details.
IL38
Servo User Constant
Range
Unit
−2
31
to 2
31
−1
−