Axis motion parameters (tree view) – Yaskawa MP2200 Machine Controller User Manual
Page 18

xviii
Axis Motion Parameters (Tree View)
The following table lists the axismotion parameters registered for each logical axis.
Register address IW (IB/IL/IF/IA) xx00 indicates the leading input register address +00.
Register address OW (OB/OL/OF/OA) xx00 indicates the leading output register address +00.
Variable Name
Register
Comments
Acceleration
OLxx36
Acceleration Value, units selected by UnitsWord
(OWxx03)
Alarm
-
Alarm
ABSEncoderOverrange
IBxx053
Absolute encoder number of rotations exceeded alarm
Active
IBxx2C0
Servo status ALM
Code
IWxx2D
Servo Alarm Code
AllMask
ILxx04
Alarm mask
Clear
OBxx00F
Clears servo alarms.
FilterTimeChanged
IBxx04B
Filter time constant changed while in motion alarm
FilterTypeChanged
IBxx04A
Filter type changed while in motion alarm
FollowingError
IBxx049
Following error exceeded alarm
HomingWhileMoving
IBxx04E
Zero point set while in motion alarm
MonitorNumber
OWxx4F
This value determines which of the last 10 alarm
codes are returned.
NegativeOvertravel
IBxx041
Positive overtravel alarm
NegativeSoftLimit
IBxx044
Negative software limit alarm
NegativeSoftLimitN
IBxx2CD
Servo status N SOT
NetworkServo
IBxx040
Servo alarm
NotHomed
IBxx04D
Zero point not set alarm
OutOfRangeParameter
IWxx01
Parameter number that is over range
PositionCompletionTimeOut
IBxx046
Positioning timeout alarm
PositionValueOutOfRange
IBxx047
Positioning out of range alarm
PositiveOvertravel
IBxx042
Negative overtravel alarm
PositiveSoftLimit
IBxx043
Positive software limit alarm
PositiveSoftLimitN
IBxx2CC
Servo status P SOT
ServoCommandTimeout
IBxx052
Servo command timeout alarm
ServoCommunication
IBxx051
Servo communication alarm
ServoCommunicationTimeout
IBxx050
Servo communication synchronization alarm
ServoNotEnabled
IBxx045
Servo OFF alarm
ServoParameterOutOfRange
IBxx04F
Servo parameter alarm
SpeedOutOfRange
IBxx048
Speed out of range alarm