4.3 SVB-01 Module Parameter Details

4-25

( 2 ) Mode 1

( 3 ) Mode 2

OW††01

Mode 1

Setting Range

Setting Unit

Default Value

0000H

OW††01

Bit 0

Deviation Abnormal Detection Error Level

Set whether excessively following errors are treated as warnings or as alarms.
0: Warning (default): Axis continues to operate even if an excessively following error is detected.
1: Alarm: Axis stops operating when an excessive following error is detected.

Related Parameters

OL††22

Deviation Abnormal Detection Value

IB††020 Warning (Excessively Following Error)
IB††049 Error (Excessively Following Error)

Bit 3

Speed Loop P/PI Switch

Switch the SERVOPACK’s speed loop between PI control and P control.
The setting is enabled when the move command or the SERVO ON command is sent.
0: PI control (default)
1: P control

Bit 4

Gain Switch

Switch the gain to the Second Gain set in the SERVOPACK parameters.
The setting is enabled when the move command or the SERVO ON command is sent.
There is no gain switch parameter in the Servo command option area in the SGD-N, SGDB-N, or
SGDH+NS100/NS115 SERVOPACKs, so the Gain Switch cannot be used.
0: Gain Switch OFF (default)
1: Gain Switch ON

Position

Phase

Speed

Torque

OW††02

Mode 2

Setting Range

Setting Unit

Default Value

0000H

OW††02

Bit 0

Monitor 2 Enabled

Disable/enable Monitor 2 in the Servo User Monitor (setting parameter OW††4E, bits 4 to 7).
0: Disabled (default)
1: Enabled
This bit is valid only when the communication mode is MECHATROLINK-I or MECHATROLINK-II
17-byte Mode.
This bit is ignored for MECHATROLINK-II 32-byte Mode.

Position

Phase

Speed

Torque