background image

4.3 SVB-01 Module Parameter Details

4-39

( 24 ) Filter Time Constant

OW††3A

S-curve Acceleration Time

Setting Range

Setting Unit

Default Value

0 to 65535

0.1 ms

0

Set the acceleration/deceleration filter time constant.
Always make sure that pulse distribution has been completed (i.e., that monitoring parameter IB††0C0 is ON) before changing
the time constant.
The actual machine operation depends on the settings in the SERVOPACK parameters. Refer to 9.4 Parameters That Are Auto-
matically Updated
for details on making parameters automatically effective.
Change the time constant for the filter set using the motion command Change Filter Type.
After setting the filter type to be used, change the time constant.
The overall flow for setting the filter time constant is as follows:

1. Select the filter type in Function 1 (setting parameter OW††03, bits 8 to B).

2. Execute the motion command Change Filter Type (CHG_FILTER).

3. Set the S-curve Acceleration Time (setting parameter OW††3A).

4. Execute the motion command Change Filter Time Constant.

Once the filter type is set using the motion command, the setting is held until the power is turned OFF or the filter type is
changed.
There are two types of acceleration/deceleration filter: An exponential acceleration/deceleration filter and a moving average
filter.
The following table shows the relationship with related parameters.

Position

Phase

Speed

Torque

OW

3A

OW

3A

OW

36

OW

3A

OW

3A

OW

38

OW

36

OW

38

Step input

No Filter

Acceleration/deceleration used

OW

38, Bits 8 to B = 0

Exponential Acceleration/Deceleration Filter

OW

38, bits 8 to B = 1

Moving Average Filter

OW

38, bits 8 to B = 2