beautypg.com

2 ) procedure – Yaskawa MP2200 Machine Controller User Manual

Page 457

background image

8.4 Sample Programming

8-41

( 2 ) Procedure

Use the following procedure to confirm operation.

The following table gives an outline of the operation when the Tuning Panel window is used.

„ Actual Application Programs

It is necessary to create routines within the actual application program in order to monitor and control
the registers corresponding to the signals and data listed in the table above.
The register numbers that correspond to the signals used in this sample program will be the register
numbers displayed under REG-No. next to DWG at the right of the Tuning Panel window.

12

Axis 2 forward JOG

S

ON/OFF

OFF

DB000010

H02.02

13

Axis 2 reverse JOG

S

ON/OFF

OFF

DB000011

H02.02

14

Axis 1 forward STEP

S

ON/OFF

OFF

DB000012

H02.01

15

Axis 1 reverse STEP

S

ON/OFF

OFF

DB000013

H02.01

16

Axis 2 forward STEP

S

ON/OFF

OFF

DB000012

H02.02

17

Axis 2 reverse STEP

S

ON/OFF

OFF

DB000013

H02.02

18

Axis 1 STEP Moving Amount

S

XXXXXXXXXX

0000000000

0214783648

2147483647

DL00010

H02.01

19

Axis 2 STEP Moving Amount

S

XXXXXXXXXX

0000000000

0214783648

2147483647

DL00010

H02.02

Servo ON

Confirm operation.

Start JOG or STEP operation.

Data Name

Tuning Panel Operation

Operation Outline

Servo ON PB

Current value OFF

→ ON

The Servomotor will turn ON and the Servo will be clamped.

Current value ON

→ OFF

Servo turned OFF.

Axis 1 forward JOG

Current value OFF

→ ON

Axis 1 rotates forward.

Current value ON

→ OFF

Axis 1 stops.

Axis 1 reverse JOG

Current value OFF

→ ON

Axis 1 rotates in reverse.

Current value ON

→ OFF

Axis 1 stops.

Axis 2 forward JOG

Current value OFF

→ ON

Axis 2 rotates forward.

Current value ON

→ OFF

Axis 2 stops.

Axis 2 reverse JOG

Current value OFF

→ ON

Axis 2 rotates in reverse.

Current value ON

→ OFF

Axis 2 stops.

Axis 1 forward
STEP

Current value OFF

→ ON

Axis 1 starts rotating forward for the moving amount set under Axis 1 STEP
moving amount.

Current value ON

→ OFF

Axis 1 STEP operation stops. Input “OFF” after executing stepping.

Axis 1 reverse
STEP

Current value OFF

→ ON

Axis 1 starts rotating in reverse for the moving amount set under Axis 1
STEP moving amount.

Current value ON

→ OFF

Axis 1 STEP operation stops. Input “OFF” after executing stepping.

Axis 2 forward
STEP

Current value OFF

→ ON

Axis 2 starts rotating forward for the moving amount set under Axis 2 STEP
moving amount.

Current value ON

→ OFF

Axis 2 STEP operation stops. Input “OFF” after executing stepping.

Axis 2 reverse
STEP

Current value OFF

→ ON

Axis 2 starts rotating in reverse for the moving amount set under Axis 2
STEP moving amount.

Current value ON

→ OFF

Axis 2 STEP operation stops. Input “OFF” after executing stepping.

Axis 1 STEP
Moving Amount

Enter any value.

Sets the STEP moving amount for axis 1.

Axis 2 STEP
Moving Amount

Enter any value.

Sets the STEP moving amount for axis 2.

INFO

This manual is related to the following products: