8.4 Sample Programming
8-41
( 2 ) Procedure
Use the following procedure to confirm operation.
The following table gives an outline of the operation when the Tuning Panel window is used.
Actual Application Programs
It is necessary to create routines within the actual application program in order to monitor and control
the registers corresponding to the signals and data listed in the table above.
The register numbers that correspond to the signals used in this sample program will be the register
numbers displayed under REG-No. next to DWG at the right of the Tuning Panel window.
12
Axis 2 forward JOG
S
ON/OFF
OFF
DB000010
H02.02
13
Axis 2 reverse JOG
S
ON/OFF
OFF
DB000011
H02.02
14
Axis 1 forward STEP
S
ON/OFF
OFF
DB000012
H02.01
15
Axis 1 reverse STEP
S
ON/OFF
OFF
DB000013
H02.01
16
Axis 2 forward STEP
S
ON/OFF
OFF
DB000012
H02.02
17
Axis 2 reverse STEP
S
ON/OFF
OFF
DB000013
H02.02
18
Axis 1 STEP Moving Amount
S
XXXXXXXXXX
0000000000
−
0214783648
2147483647
DL00010
H02.01
19
Axis 2 STEP Moving Amount
S
XXXXXXXXXX
0000000000
−
0214783648
2147483647
DL00010
H02.02
Servo ON
Confirm operation.
Start JOG or STEP operation.
Data Name
Tuning Panel Operation
Operation Outline
Servo ON PB
Current value OFF
→ ON
The Servomotor will turn ON and the Servo will be clamped.
Current value ON
→ OFF
Servo turned OFF.
Axis 1 forward JOG
Current value OFF
→ ON
Axis 1 rotates forward.
Current value ON
→ OFF
Axis 1 stops.
Axis 1 reverse JOG
Current value OFF
→ ON
Axis 1 rotates in reverse.
Current value ON
→ OFF
Axis 1 stops.
Axis 2 forward JOG
Current value OFF
→ ON
Axis 2 rotates forward.
Current value ON
→ OFF
Axis 2 stops.
Axis 2 reverse JOG
Current value OFF
→ ON
Axis 2 rotates in reverse.
Current value ON
→ OFF
Axis 2 stops.
Axis 1 forward
STEP
Current value OFF
→ ON
Axis 1 starts rotating forward for the moving amount set under Axis 1 STEP
moving amount.
Current value ON
→ OFF
Axis 1 STEP operation stops. Input “OFF” after executing stepping.
Axis 1 reverse
STEP
Current value OFF
→ ON
Axis 1 starts rotating in reverse for the moving amount set under Axis 1
STEP moving amount.
Current value ON
→ OFF
Axis 1 STEP operation stops. Input “OFF” after executing stepping.
Axis 2 forward
STEP
Current value OFF
→ ON
Axis 2 starts rotating forward for the moving amount set under Axis 2 STEP
moving amount.
Current value ON
→ OFF
Axis 2 STEP operation stops. Input “OFF” after executing stepping.
Axis 2 reverse
STEP
Current value OFF
→ ON
Axis 2 starts rotating in reverse for the moving amount set under Axis 2
STEP moving amount.
Current value ON
→ OFF
Axis 2 STEP operation stops. Input “OFF” after executing stepping.
Axis 1 STEP
Moving Amount
Enter any value.
Sets the STEP moving amount for axis 1.
Axis 2 STEP
Moving Amount
Enter any value.
Sets the STEP moving amount for axis 2.