7 ) motion command – Yaskawa MP2200 Machine Controller User Manual
Page 148

4 Motion Parameters
4.3.2 Motion Setting Parameter Details
4-28
( 7 ) Motion Command
OW08
Motion Command
Setting Range
Setting Unit
Default Value
0 to 26
−
0
Set motion commands.
0: NOP
No command
1: POSING
Positioning
2: EX_POSING
External Positioning
3: ZRET
Zero Point Return
4: INTERPOLATE
Interpolation
5: ENDOF_
INTERPOLATE
Reserved
6: LATCH
Latch
7: FEED
JOG Operation
8: STEP
STEP Operation
9: ZSET
Zero Point Setting
10: ACC
Change Linear Acceleration Time Constant
11: DCC
Change Linear Deceleration Time Constant
12: SCC
Change Filter Time Constant
13: CHG_FILTER
Change Filter Type
14: KVS
Change Speed Loop Gain
15: KPS
Change Position Loop Gain
16: KFS
Change Feed Forward
17: PRM_RD
Read SERVOPACK Parameter
18: PRM_WR
Write SERVOPACK Parameter
19: ALM_MON
Monitor SERVOPACK Alarms
20: ALM_HIST
Monitor SERVOPACK Alarm History
21: ALMHIST_CLR
Clear SERVOPACK Alarm History
22: ABS_RST
Reset Absolute Encoder
23: VELO
Speed Reference
24: TRQ
Torque Reference
25: PHASE
Phase Reference
26: KIS
Change Position Loop Integration Time Constant
Refer to Chapter 5 Motion Commands for details.
Position
Phase
Speed
Torque