Yaskawa MP2200 Machine Controller User Manual
Page 242

5 Motion Commands
5.2.2 External Positioning (EX_POSING)
5-12
(
Note)
: Parameters only for the SVB-01 Module.
[ b ] Monitoring Parameters
OL36
Linear Acceleration
Time
Set the rate of acceleration or acceleration time constant for positioning.
OL38
Linear Deceleration
Time
Set the rate of deceleration or deceleration time constant for positioning.
OW3A
S-Curve Acceleration
Time
Set the acceleration/deceleration filter time constant. Exponential acceleration/deceleration or a
moving average filter can be selected in OW03.
Change the setting only after pulse distribution has been completed for the command
(IB0C0 is ON).
OL46
External Positioning
Move Distance
Set the moving amount to move after the external positioning signal is input.
(cont’d)
Parameter
Name
Setting
Parameter
Name
Monitor Contents
IB001
Servo ON
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command Type
Response
Indicates the motion command that is being executed.
The response code is 2 during EX_POSING command execution.
IB090
Command Executing
The Command Executing bit will turn ON during EX_POSING command execution and then
turn OFF when command execution has been completed.
IB091
Command Hold
Completed
Turns ON when a deceleration to a stop has been completed as the result of setting the
Command Pause bit to 1 (OB090 to 1) during EX_POSING command execution.
IB093
Command Error End
Turns ON if an error occurs during EX_POSING command execution. The axis will
decelerate to a stop if it is moving. Turns OFF when another command is executed.
IB098
Command Execution
Completed
Turns ON when EX_POSING command execution has been completed.
IB0C0
Distribution
Completed
Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.
IB0C1
Positioning
Completed
Turns ON when pulse distribution has been completed and the current position is within the
Positioning Completed Width. OFF in all other cases.
IB0C2
Latch Completed
This bit turns OFF when a new latch command is executed and turns ON when the latch has
been completed. The latched position is stored as the Machine Coordinate Latch Position
(monitoring parameter IL18).
IB0C3
Position Proximity
The operation depends on the setting of the Positioning Completed Width 2 (setting parameter
OL20).
OL20 = 0: Turns ON when pulse distribution has been completed (DEN = ON).
OL20
≠0: Turns ON when MPOS - APOS< Position Proximity Setting even if pulse
distribution has not been completed.
OFF in all other cases.
IL18
Machine Coordinate
Latch Position
Stores the current position in the machine coordinate system when the latch signal turned ON.