4 Motion Parameters
4.2.2 Setting Parameter List
4-10
OL16
Secondly Speed
Compensation
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
Yes
Yes
OW18
Speed Override
1 = 0.01%
Yes
Yes
OW19
-
Reserved
OW1A
General-purpose AO1
1 = 0.001 V
Yes
OW1B
General-purpose AO2
1 = 0.001 V
Yes
OL1C
Position Reference Setting
1 = 1 reference unit
Yes
Yes
Yes
OL1E
Positioning Completed Width
1 = 1 reference unit
Yes
Yes
OL20
Positioning Completed Width
2
1 = 1 reference unit
Yes
Yes
OL22
Deviation Abnormal Detection
Value
1 = 1 reference unit
Yes
Yes
OL24
Position Compensation
1 = 1 reference unit
Yes
OW26
Position Complete Timeout
1 = 1 ms
Yes
Yes
OW27
-
Reserved
OL28
Phase Compensation
1 = 1 reference unit
Yes
Yes
OL2A
Latch Zone Lower Limit
Setting
1 = 1 reference unit
Yes
Yes
OL2C
Latch Zone Upper Limit
Setting
1 = 1 reference unit
Yes
Yes
OW2E
Position Loop Gain
1 = 0.1/s
Yes
Yes
OW2F
Speed Loop Gain
1 = 1 Hz
Yes
OW30
Speed Feed Forward
Compensation
1 = 0.01% (percentage of distribution segment)
Yes
Yes
OW31
Speed Amends
1 = 0.01% (percentage of rated speed)
Yes
Yes
Yes
OW32
Position Integration Time
Constant
1 = 1 ms
Yes
Yes
OW33
Primary Lag Time Constant
1 = 1 ms
Yes
OW34
Speed Integration Time
Constant
1 = 0.01 ms
Yes
OW35
-
Reserved
OL36
Linear Acceleration Time
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
Yes
Yes
OL38
Linear Deceleration Time
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
Yes
Yes
OW3A
S-curve Acceleration Time
1 = 0.1 ms
Yes
Yes
Yes
OW3B
Bias Speed for Exponential
Acceleration/Deceleration
Filter
Unit is according to OW03, bits 0 to 3 (Speed Unit).
Yes
Yes
(cont’d)