2 ) related parameters, 3 ) timing charts – Yaskawa MP2200 Machine Controller User Manual
Page 353

5.3 Motion Subcommands
5-123
( 2 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
( 3 ) Timing Charts
[ a ] Normal End
Parameter
Name
Setting Contents
OW0A
Motion Subcommand
The Monitor Status command is executed when this parameter is set to 3.
OW4E
Servo User Monitor
Set the information (managed by the Servo Driver) that you want to monitor.
Parameter
Name
Monitoring Contents
IW0A
Motion Subcommand
Response Code
Indicates the motion subcommand that is being executed.
The response code is 3 during SMON command execution.
IB0B0
Command Executing
Turns ON during SMON command execution and turns OFF when execution has
been completed.
IB0B3
Command Error End
Turns ON if an error occurs during SMON command execution. Turns OFF when
another command is executed.
IB0B8
Command Execution
Completed
Turns ON when SMON command execution has been completed.
IW2F
Servo Driver User
Monitor Information
Stores either the monitor selection or the data actually being monitored in the user
monitor.
IL34
Servo User Monitor 4
Stores the result of the selected monitor operation.
OW
0A=3 (SMON)
IW
0A=3 (SMON)
IB
0B0 (BUSY)
IW
2D, bits12 to 15
Undefined
Monitor 4 = Set value
IB
0B8 (COMPLETE)
IB
0B3 (FAIL)
IL
34
Undefined
Monitoring result