4 ) timing charts – Yaskawa MP2200 Machine Controller User Manual
Page 319

5.2 Motion Command Details
5-89
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command 
Type Response 
Indicates the motion command that is being executed. 
The response code will be 17 during PRM_RD command execution. 
IB090
Command Executing
Turns ON during PRM_RD command execution and turns OFF when execution has 
been completed. 
IB091
Command Hold 
Completed 
Always OFF for PRM_RD command.
IB093
Command Error End
Turns ON if an error occurs during PRM_RD command execution. Turns OFF when 
another command is executed. 
IB098
Command Execution 
Completed
Turns ON when PRM_RD command execution has been completed.
IW36
Servo Constant 
Number
Stores the number of the SERVOPACK parameter that was read.
IL38
Servo User Constant
Stores the data of the SERVOPACK parameter that was read.
OW
08 = 17 (PRM_RD)
IW
08 = 17 (PRM_RD)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length 
of time
OW
08 = 17 (PRM_RD)
IW
08 = 17 (PRM_RD)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length 
of time