4.4 SVA-01 Module Parameter Details
4-81
( 25 ) Filters
OW3A
S-curve Acceleration Time
Setting Range
Setting Unit
Default Value
0 to 65535
0.1 ms
0
Sets the acceleration/deceleration filter time constant.
Always verify that pulse distribution has been completed (monitoring parameter IB0C0 is ON) before changing the time
constant.
After setting the filter type to be used, change the time constant.
Once the filter type is set, the setting is held until the power is turned OFF or the filter type is changed.
There are two types of acceleration/deceleration filter: an exponential acceleration/deceleration filter and a moving average
filter.
The following table shows the relationship with related parameters.
OW3B
Bias Speed for Exponential
Acceleration/Deceleration
Filter
Setting Range
Setting Unit
Default Value
0 to 32767
Speed Units (setting parameter
OW03, bits 0 to 3)
0
Set the bias speed for exponential acceleration/deceleration with bias.