5.2 Motion Command Details
5-75
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
Parameter
Name
Setting
OW03
Function 1
Set the speed unit, acceleration/deceleration unit, and filter type.
OW08
Motion Command
The linear acceleration time constant is changed when this parameter is set to 10.
OB090
Command Pause
This parameter is ignored for ACC command.
OB091
Command Abort
This parameter is ignored for ACC command.
OL36
Linear Acceleration
Time
Set the acceleration for feeding as the acceleration time.
Parameter
Name
Monitor Contents
IL02
Warning
Stores the most current warning.
IL04
Alarm
Stores the most current alarm.
IW08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 10 during ACC command execution.
IB090
Command Executing
Turns ON during ACC command execution and turns OFF when execution has been
completed.
IB091
Command Hold
Completed
Always OFF for ACC command.
IB093
Command Error End
Turns ON if an error occurs during ACC command execution. Turns OFF when another
command is executed.
IB098
Command Execution
Completed
Turns ON when ACC command execution has been completed.
OW
08 = 10 (ACC)
IW
08 = 10 (ACC)
IB
090 (BUSY)
Undefined length
of time
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined length
of time
OW
08 = 10 (ACC)
IW
08 = 10 (ACC)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)