6 monitor status (smon), 6 monitor s, 6 monitor status (smon) -122 – Yaskawa MP2200 Machine Controller User Manual
Page 352: 1 ) operating procedure
5 Motion Commands
5.3.6 Monitor Status (SMON)
5-122
5.3.6 Monitor Status (SMON)
When the SMON command is executed, the data specified in Monitor 4 of the Servo User Monitor is
stored in Servo User Monitor 4 (monitoring parameter IL34).
The following table shows the data that can be specified in the User Monitor. Refer to your
SERVOPACK manual for details on the monitored data.
This command will end with a Command Error End if it is executed with a communications method
other than MECHATROLINK-II (32 byte).
( 1 ) Operating Procedure
Set Value
Name
Contents
0
POS
Reference coordinate system's reference position (after reference
filter)
1
MPOS
Machine coordinate system's reference position
2
PERR
Following error
3
APOS
Machine coordinate system's feedback position
4
LPOS
Machine coordinate system's feedback latch position
5
IPOS
Reference coordinate system's reference position (before reference
filter)
6
TPOS
Reference coordinate system's target position
7
−
−
8
FSPD
Feedback Speed
9
CSPD
Reference speed
A
TSPD
Target speed
B
TRQ
Torque reference (Rated torque is 100%.)
C
−
−
D
−
−
E
OMN1
Optional monitor 1 (Actual content set in parameters.)
F
OMN2
Optional monitor 2 (Actual content set in parameters.)
No.
Execution Conditions
Confirmation Method
1
Motion subcommand execution must be completed.
IW0A is 0 and IB0B0 is OFF.
Execute SMON motion subcommand.
• Set OW0A to 3.
Reads the information managed by the Servo Driver
and stores the code in the monitoring parameter.
• IW0A will be 3 during command execution.
• IB0B0 will be ON during command
processing.
Monitoring is completed.
• IW0A is 3 and IB0B0 is OFF.
Execute NOP motion command.
• Set OW0A to 0.