beautypg.com

4 ) alarm – Yaskawa MP2200 Machine Controller User Manual

Page 167

background image

4.3 SVB-01 Module Parameter Details

4-47

( 4 ) Alarm

IL††04

Alarm

Range

Unit

IL††04

Bit 0

Servo Driver Error

This bit turns ON when there is an alarm in the SERVOPACK for MECHATROLINK communication.
The content of the alarm can be confirmed using the Servo Alarm Code (monitoring parameter
IW††2D).
OFF: No Servo Driver alarm
ON: Servo Driver alarm occurred

Bit 1

Positive Overtravel

This bit turns ON when the positive overtravel signal is input and a move command is executed in the
positive direction. For details, refer to 9.2 Overtravel Function.
OFF: No positive overtravel
ON: Positive overtravel occurred

Bit 2

Negative Overtravel

This bit turns ON when the negative overtravel signal is input and a move command is executed in the
negative direction. For details, refer to 9.2 Overtravel Function.
OFF: No negative overtravel
ON: Negative overtravel occurred

Bit 3

Positive Soft Limit (Positive Software Limit)

This bit turns ON if a move command that exceeds the positive software limit is executed with the
following conditions:

• Zero point return has been completed
• The positive software limit function is enabled
• A finite length axis is selected.

For details, refer to 9.3 Software Limit Function.
OFF: In positive software limit range
ON: Outside positive software limit range

Bit 4

Negative Soft Limit (Negative Software Limit)

This bit turns ON if a move command that exceeds the negative software limit is executed with the
following conditions:

• Zero point return has been completed
• The negative software limit function is enabled
• A finite length axis is selected.

For details, refer to 9.3 Software Limit Function.
OFF: In negative software limit range
ON: Outside negative software limit range

Bit 5

Servo OFF

This bit turns ON when a move command is executed during Servo OFF status.
OFF: Servo ON
ON: Servo OFF

Bit 6

Positioning Time Over

This bit turns ON when positioning is not completed within the specified time after the end of pulse
distribution. The time is set for the Position Complete Timeout (setting parameter OW††26).
OFF: No timeout
ON: Timeout occurred

Bit 7

Excessive Positioning Moving Amount

This bit turns ON when a moving amount is specified that exceeds the setting range for the positioning
moving amount.
OFF: Moving amount normal
ON: Excessive moving amount