Each GPI out on this GPI-1501 card can be programmed to respond to a different alarm from
a different card. The eight output relays on the selected card are shown. The names of the
GPIs are set in the GPI I/O Config panel of the GPI card itself.
•
Pressed = high
•
Released = low
8. Click OK when done, or Cancel to leave the status unchanged
This new event appears in the Actions window in the Alarm Properties panel.
Notes
• If you leave it at State, the GPI is not programmed to respond to this alarm,
and can be assigned to a different alarm.
• You can use the labels to identify the alarm source once it is set.
Note: You can edit or delete the event by selecting the GPI-1501 action and clicking
Edit or Remove, respectively.
See also
For more information, see:
•
"GPI-1501 I/O Module (Densité Card)"
• the Densité Series GPI-1501 General Purpose Interface I/O Module Guide to Installation
and Operation (M906-9900-100).