Grass Valley iControl V.4.43 User Manual
Page 528

iControl and SNMP
Example
518
clear TRAP‐TYPE
ENTERPRISE miranda
VARIABLES { trapDevice, trapAlarm }
DESCRIPTION
"A clear trap means that the alarm condition that existed has now been
cleared."
::= 100
error TRAP‐TYPE
ENTERPRISE miranda
VARIABLES { trapDevice, trapAlarm }
DESCRIPTION
"A error trap means that a error alarm condition is present"
::= 200
END
When the SCP probe freeze detection alarm goes from an error state to a normal state, a trap is
sent to the specified trap target. Here’s the output of a trap catcher application.
Figure 8-126
The trap number is shown in the Specific Type field. Variable bindings included in the trap are
the
trapDevice
and the
trapAlarm
which are shown in the Message field. From the
trapDevice
, the SNMP manager can determine which card generated the trap. In this case it is
the card with the following long ID:
icontrol_product1_RACK_D11_FRAME_Densité_SLOT_1_31
This long ID can be interpreted as follows: