Configuring Fingerprint Analyzer Service Alarms
The Fingerprint Analysis feature uses alarms to communicate comparison data to a user in
real-time. You can configure the following parameters of Fingerprint Analyzer Service alarms:
• Alarm severity sent to the GSM (GSM contribution)
• Whether to log events
To configure Service alarms
1. On the Configuration tab, in the Fingerprint comparison setup area, click Alarm config.
Sample workflow: Initial configuration tasks
1.
Enable the Audio/Video Fingerprint Analyzer Service on the Webmin page of your
Application Server (see
"Starting & Stopping iControl Services"
2.
Open Audio Video Fingerprint Analyzer (see
).
3.
Configure Fingerprint Analyzer Service alarms according to your individual needs
(see
).
4.
Create a comparison group of input sources, including a reference source (see
5.
Assign all desired input sources (including the reference source) to your comparison group
(see
).
6.
Designate one of the assigned sources as the Reference (see
Reference Source in a Comparison Group"
7.
Configure each assigned source’s channel assignments, as required (see
REQUIREMENT
Before beginning this procedure, make sure you have opened Audio Video Fingerprint
Analyzer (see
).