3
PM Designer Operation Manual
3-38
CHAPTER 3 CREATING PANEL APPLICATIONS
3.6.3. Command Block Settings (Type A)
This section describes how to configure the type A command block using the Command Block page of the Command &
Status dialog box. The following is an example of the Command Block page.
The following table describes each property in the Command Block page.
Property
Description
Arrangement
Select
Default if you want the command words to be in the default order in
the command block. Select
Custom if you want to arrange each command
word in the command block by yourself.
Screen Switching
Register
Check this option so you can use the word to change the main screen or
display a window screen by setting the word to the number of the desired
screen.
Reset SSR to Zero
If this option is selected, the panel always resets the Screen Switching
Register to zero when it detects a nonzero value is in the word. If this option
is not selected, the panel resets the Screen Switching Register to zero only
when the specified screen is valid and not displayed yet.
Parameter One Register
Check this option so you can this word to specify the No. 1 parameter for
the specified operation.
Command Flags #0 ~ #15
(Command Flag Word)
Check this option so you can use the command flags to request the panel
to do the specified operations.
Trigger Bits #0 ~ #15
(Low Trigger Word)
Check this option if you need any of the trigger bits in the word for your
application.
Parameter Two Register
Check this option so you can this word to specify the No. 2 parameter for
the specified operation.
Command
Word
Trigger Bits #16 ~ #31
(High Trigger Word)
Check this option if you need any of the trigger bits in the word for your
application.
Continued