4

7

PM Designer Operation Manual

7-11

CHAPTER 7 DISPLAYING AND INPUTTING DATA

7.2.4. Advanced Settings

This section describes how to define the advanced settings for a numeric display. The following is an example of the
Advanced page of the Numeric Display property sheet.

The following table describes each property in the Advanced page.

Property

Description

Check this option if you want the value of the monitored variable to be displayed in a
scaled manner. The following is the scaling formula.

Displayed Value = Monitored Value * Gain + Offset
Note: The Gain and Offset are 32-bit floating point numbers. They have at most 6
significant digits. The rounding and truncation may happen.

Gain

The Gain of the scaling formula.

Scaling

Offset

The Offset of the scaling formula.

Check this option if you want the numeric display to display the value with different
color when the value is below the specified low limit or over the specified high limit.

Variable Range

Check this option if the low limit and high limit are specified by the designated
variables at runtime.

Low Limit

Specifies the low limit when the Variable Range is not selected.

When the Variable Range is selected, this property specifies the variable that stores

the low limit at runtime. Click

to enter an address. Click

to select a tag.

High Limit

Specifies the high limit when the Variable Range is not selected.

When the Variable Range is selected, this property specifies the variable that stores

the high limit at runtime. Click

to enter an address. Click

to select a tag.

Text Color

The text color for the high limit.

High
Color

BG Color

The shape’s BG color for the high limit.

Text Color

The text color for the low limit.

Range
Display

Low
Color

BG Color

The shape’s BG color for the low limit.