beautypg.com

Pm designer operation manual – B&B Electronics WOP-2121V-N4AE - Manual User Manual

Page 442

background image

4

14

PM Designer Operation Manual

14-33

CHAPTER 14 USING MACROS

14.4.14. Screen Operation

OPEN_WS

Format

OPEN_WS P1

Data Type

U

Function

The number of the window screen to be opened. This command will not open the specified
screen if it is a normal screen or menu screen. The macro commands following this command
will not be executed until the opened window screen is closed. Also, when a screen's Cycle
macro is waiting for the closing of the window screen opened by this command, that screen can
not be closed or switched by any means.

P1 (I/C)

The number of the window screen to be opened. If the screen number indicates to normal
screen or menu screen, no screen will be opened.

CLOSE_WS

Format CLOSE_WS
Function

Closes the window screen that was opened by the macro command OPEN_WS.