Pm designer operation manual – B&B Electronics WOP-2121V-N4AE - Manual User Manual
Page 307

4
8
PM Designer Operation Manual
8-31
Property
Description
Read Address
Data Type: 32-bit; Number of Data Sets: 1
Word
Description
Word
Description
0,1
Actual number of data points
8,9
Y value of data point 1
2,3
X value of data point 0
…
…
4,5
Y value of data point 0
4n+2, 4n+3
X value of data point n
6,7
X value of data point 1
4n+4, 4n+5
Y value of data point n
Data Type: 32-bit; Number of Data Sets: 2
Word
Description
Word
Description
0,1
Actual number of data points
12,13
Y value of data point 1; Data set 1
2,3
X value of data point 0; Data set 1
14,15
X value of data point 1; Data set 2
4,5
Y value of data point 0; Data set 1
16,17
Y value of data point 1; Data set 2
6,7
X value of data point 0; Data set 2
…
…
8,9
Y value of data point 0; Data set 2
8n+6,
8n+7
X value of data point n; Data set 2
10,11
X value of data point 1; Data set 1
8n+8,
8n+9
Y value of data point n; Data set 2
Data Type: 32-bit; Number of Data Sets: 8
Word
Description
Word
Description
0,1
Actual number of data points
22,23
X value of data point 0; Data set 6
2,3
X value of data point 0; Data set 1
24,25
Y value of data point 0; Data set 6
4,5
Y value of data point 0; Data set 1
26,27
X value of data point 0; Data set 7
6,7
X value of data point 0; Data set 2
28,29
Y value of data point 0; Data set 7
8,9
Y value of data point 0; Data set 2
30,31
X value of data point 0; Data set 8
10,11
X value of data point 0; Data set 3
32,33
Y value of data point 0; Data set 8
12,13
Y value of data point 0; Data set 3
34,35
X value of data point 1; Data set 1
14,15
X value of data point 0; Data set 4
36,37
Y value of data point 1; Data set 1
16,17
Y value of data point 0; Data set 4
…
…
18,19
X value of data point 0; Data set 5
32n+30,
32n+31
X value of data point n; Data set 8
20,21
Y value of data point 0; Data set 5
32n+32,
32n+33
Y value of data point n; Data set 8
Number of
Data Sets
Specifies how many data sets that the scatter chart will display. A line chart can display up to 8 sets
of data.
Maximum
Number of
Data Points
Per Data Set
Specifies the maximum number of data points that the scatter chart will display for every data set. A
scatter chart can display up to 255 data points for one data set.
Note: The actual number of data points for every data set is specified at runtime. The actual number
must not exceed the maximum number.
Show Mark
Check this option so the scatter chart will show a square mark on every data point.
Show Line
Check this option so the scatter chart will display a line between two adjacent data points of a data
set.
Clear Trigger
The bit variable that triggers the scatter chart to clear its content when its state changes from off to
on. Click
to enter an address for this field. Click
to select a tag for this field.
Continued
CHAPTER 8 GRAPHS AND CHARTS