Pm designer operation manual – B&B Electronics WOP-2121V-N4AE - Manual User Manual
Page 318

9
PM Designer Operation Manual
9-8
CHAPTER 9 ANIMATED OBJECTS
Property
Description
Monitor Address
Specifies the variable that controls the dynamic circle.
Click
to enter an address for this field. Click
to select a tag for this field.
The following table shows the data arrangement of the variable.
Data Type
Controllable
16-Bit Unsigned Int.
16-Bit Signed Int.
16-Bit BCD
32-Bit Unsigned Int.
32-Bit Signed Int.
32-Bit BCD
Center
Radius
FG Color
W0
FG Color
W0,1
FG Color
Center
Radius
FG Color
W0
Radius
W0,1
Radius
Center
Radius
FG Color
W0
Radius
W1
FG Color
W0,1
Radius
W2,3
FG Color
Center
Radius
FG Color
W0
X
W1
Y
W0,1
X
W2,3
Y
Center
Radius
FG Color
W0
X
W1
Y
W2
FG Color
W0,1
X
W2,3
Y
W4,5
FG Color
Center
Radius
FG Color
W0
X
W1
Y
W2
Radius
W0,1
X
W2,3
Y
W4,5
Radius
Center
Radius
FG Color
W0
X
W1
Y
W2
Radius
W3
FG Color
W0,1
X
W2,3
Y
W4,5
Radius
W6,7
FG Color
Note: About the color values, see ?, ?.
Center
Check this option when you want to control the center.
Radius
Check this option when you want to control the radius.
Controllable
FG Color
Check this option when you want to control the FG color. This option is available
when the Circle is Solid and the Pattern is not the solid white.
Check this option if you want the dynamic circle to be filled with the selected
pattern.
Pattern
Select a pattern for filling the dynamic circle.
FG Color
Select a color for painting the black part of the pattern. This item is available when
the Pattern is not solid white.
Solid
BG Color
Select a color for painting the white part of the pattern.
Check this option if you want the dynamic circle to have a border.
Circle
Border
Border Color
The border color.