B&B Electronics NTSA-CAT5E - Datasheet User Manual
Ntsa-cat5e surge arrester, Installation instructions 2114a
instructions 2114A
1
Installation Instructions 2114A
NTSA-CAT5e Surge Arrester
THE INDUSTRIAL NETWORK COMPANY
N-Tron Corp.
820 S. University Blvd.
Suite 4E
Mobile, Alabama
Phone: 251-342-2164
www.n-tron.com
REV A • Issued August 2005
NS 35/7.5
DIN-rail
NS 32
Mounting Rail
NS 35/15
DIN-rail
94.0 mm (3.70 in.)
90.0 mm (3.54 in.)
45 mm
(1.77 in.)
50 mm
(1.97 in.)
52.5 mm
(2.06 in.)
25.4 mm
(1.00 in.)
2114A004
Universal
Mounting
Foot
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
2114A003
2114A002-3
2114A005-1
Specifications
General
Electrical
Environmental
Degree of protection per IEC 60529/EN 60 529 .......... IP20
U Max. Continuous Operating Voltage (MCOV) ...... 7 V dc
I touch current (leakage) ......................................... 1 mA
Temperature range .......... -40°C to +80 C (-40°F to 176°F)
C
C
I nominal current (max. cont. operating current)....... 1.5 A
I max single impulse discharge (8/20 µs):
(line - line/line - ground) ............................. 350 A/2.5 kA
residual voltage IN per IEC 61643-21: line - line
(C1-500V)/line - ground (C2-4 kV) .......... 45 V/s 850 V
a input attenuation in a 100/150
system (typical) ................................... 1 db bis 100 MHz
N
n
p
≤
U
≤
Ω
l