5 meas ph - additional measured values, Additional measured values – Metrohm tiamo 2.1 (ProcessLab) User Manual
Page 887
■■■■■■■■■■■■■■■■■■■■■■
5 Method
tiamo 2.1 (ProcessLab)
■■■■■■■■
871
Window
A range (window) can be defined on the measured value axis or on the time
axis. The break point evaluation will only be carried out in the defined win-
dow. Only the first break point in the defined window will be recognized.
Selection
Measured value | time | off
Default value
off
Lower limit
Value for the lower limit of the window.
Time for the lower limit of the window.
Window = Measured value
Range
-20,000 ... -20,000 pH
Default value
20,000 pH
Window = Time
Range
0 ... 999999 s
Default value
0 s
Upper limit
Value for the upper limit of the window.
Value for the upper limit of the window.
Window = Measured value
Range
-20,000 ... 20,000 pH
Default value
20,000 pH
Window = Time
Range
0 ... 999999 s
Default value
999999 s
5.6.4.2.5
MEAS pH - Additional measured values
Tab: Method
▶ MEAS pH ▶ Properties... ▶ Additional measured values
Command name
Name of the command.
Input
25 characters
A maximum of 6 additional measured values can be defined here which can
then be saved together with the measured values present in the default
settings in additional measured value columns Calculated # or External
# in the measuring point list.