5 wait, 1 wait - overview, Wait – Metrohm tiamo 2.1 (ProcessLab) User Manual
Page 1175
■■■■■■■■■■■■■■■■■■■■■■
5 Method
tiamo 2.1 (ProcessLab)
■■■■■■■■
1159
The input field contains the expression for the condition(s) which can be
created or edited with the formula editor after pressing on
or double-
clicking in the text field (see Chapter 2.4, page 23). If the condition is fulfilled
(evaluation of the formula gives the result 1 = true), then the loop will be
canceled when the LOOP command is called.
Input
1000 characters
Default value
'empty'
5.6.10.5
WAIT
5.6.10.5.1
WAIT - Overview
Dialog window: Method
▶ WAIT ▶ Properties... ▶ WAIT - 'Command name'
Command for halting the method run and for output of messages.
Appearance
The command has the following appearance:
Parameters
The parameters for the command WAIT are configured in the following
dialog window:
■
Command variables
The following command variables are generated in the method run by the
command WAIT and can be used in formulas under the designation 'Com-
mand name.Variable designation':
Identifi-
cation
Description
.BSY
Command status; 1 = BUSY, HOLD or ERROR; 0 =
READY; invalid (variable not available) = Command has
not ever been started
.FIN
Command status; 1 = Command has been ended at
least once, 0, invalid (variable not available) = Com-
mand has never been ended