PROFINET communication

Parameterising the counter

Two counters 32 bits, 24 V DC − EPM−S601

12

l

671

EDSIO1000 EN 7.0

Parameter data

Data set

Name

Description/value

Lenze

No.

Byte

00

h

0

Diagnostics

A diagnostic alarm occurs if the same event triggers a
further process alarm during a process alarm processing.
Bits 5 ... 0: reserved
Bit 6: Diagnostic alarm (0 = inhibited; 1 = enabled)
Bit 7: Reserved
Other values are not permissible!

00

h

01

h

0

Input frequency
counter 1, track A

Filters for instance serve to filter signal peaks in the case
of an unclean input signal.
2 (02

h

): 100 kHz

3 (03

h

): 60 kHz

4 (04

h

): 30 kHz

6 (06

h

): 10 kHz

7 (07

h

): 5 kHz

8 (08

h

): 2 kHz

9 (09

h

): 1 kHz

Other values are not permissible!

02

h

1

Input frequency
counter 1, track B

02

h

2

Input frequency
counter 2, track A

02

h

3

Input frequency
counter 2, track B

02

h

80

h

0

Alarm response
counter 1

Setting activates process alarm
Bits 1 ... 0: reserved
Bit 2: Proc. alarm overflow
Bit 3: Proc. alarm underflow
Bit 4: Proc. alarm comparison value
Bit 5: Proc. alarm final value
Bits 7 ... 6: Reserved

00

h

1

Counter function
counter 1

Bit 5 ... 0:

000000

b

= counting continuously

000001

b

= once: forwards

000010

b

= once: backwards

000100

b

= once: no main counting direction

001000

b

= periodically: forwards

010000

b

= periodically: backwards

100000

b

= periodically: no main counting direction

Bits 7 ... 6: Reserved

00

h

2

Comparator
counter 1

Bits 2 ... 0: Comparison bit is set (... if condition is met)

000

b

= never

001

b

= count value

³ comparison value

010

b

= count value

£ comparison value

100

b

= count value = comparison value

Bit 3: Invert counting direction track B

0 = no (do not invert)
1 = yes (invert)

Bits 7 ... 4: Reserved

00

h

3

Signal evaluation
counter 1

Bits 2 ... 0: Signal evaluation

000

b

= counter deactivated (the other parameter

details for the counter are ignored)
001

b

= rotary transducer single (at A and B)

010

b

= rotary transducer double (at A and B)

011

b

= rotary transducer quadruple (at A and B)

100

b

= direction (pulse at A and direction at B)

Bits 6 ... 3: Reserved
Bit 7: Gate function (internal gate)

0= abort (counting process starts again from loading
value)
1 = interrupt (counting process is continued with
counter content)

00

h